. MGE UPS SYSTEMS Pulsar EXtreme 2200C / 3200C Installation and user manual - Page 1 34007532EN/AA.
Eaton 5P 650 - Battery installation (EN). How to change the UPS's battery - Eaton 5P 650.
Pulsar EXtreme C at the end of its service life. To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar EXtreme C range, we invite you to visit our web site at www.mgeups.com or contact your MGE UPS SYSTEMS representative. Foreword Using this document Information may be found primarily by consulting: the contents, the index. Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication.
Audio indication. In the illustrations on the following pages, the symbols below are used: LED off.
Page 4 - 34007532EN/AA. Standard positions.7 Rack position.7 Tower position.7 Back. 8 Pulsar EXtreme 2200C.8 Pulsar EXtreme 3200C.8 Pulsar EXB 2200 / 3200. 8 Control panel.9 Installation Unpacking and checks.
10 Installation in rack position. Contents Maintenance Troubleshooting. 20 Replacement of the battery module.22 Environment.
24 Appendices Technical characteristics.25 Glossary.26 Index. 27 Page 6 - 34007532EN/AA. 86.5 mm (2U) P U L S A R E X t r e m e BYPASS 100% test www. Mgeu ps.co Pulsar EXtreme 2200C: 35.3 Kg Pulsar EXtreme 3200C: 35.7 Kg Tower position www.m geups.
Com - Page 7 34007532EN/AA. USB communications port. Four outlets for direct connection of protected equipment. Two programmable outlets (outlet 1 and 2).
Output circuit breakers. Pulsar EXtreme 3200C Socket for connection to AC-power 9 10 11 12 source.
Connector for an additional battery module. Presentation 1.3 Control panel BYPASS test 100% ON / OFF. Operation on battery power. Operation in ON-LINE mode (backup power available). Alarms battery load Operation on bypass (no backup power available). Remaining 100% 100% Status of programmable outlet 2: Supplied with power. Installation 2.1 Unpacking and parts check Cord for connection to the AC-power source for Pulsar EXtreme 3200C versions only (for the Pulsar EXtreme 2200C version, use the power cord of the protected equipment).
Two cords for connection of the protected equipment. Follow steps 1 to 6 for rack mounting of the UPS on the rails. 100% BYPA test The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS. Note for step 3: It is possible to adjust the positions of the front brackets. Page 2EN/AA. Installation 2.3 Installation in tower position Connect the two supports for the upright position.
P U L S A R E X t r e m e www.mge ups.c Page 12 - 34007532EN/AA. RS232 2 or USB 3 communications port on the UPS.
The UPS can now communicate with all MGE UPS SYSTEMS supervision, set-up or safety software. The RS232 and USB communications ports cannot operate simultaneously. 2.5 Installation of the communications-card option. AC-power socket 7 and then to the AC-power wall outlet.
Pulsar EXtreme 3200C: connect the supplied power cord 28 (250 V, 16 A) to the AC-power socket 7 and then to the AC- power wall outlet. Operation 3.1 Start-up The protected equipment connected to the UPS can be energised, whether AC input power is available or not. Caution: the AC input power source must be present when energising for the first time. Press the ON / OFF button 16. The buzzer beeps and all the LEDs go ON. Operation 3.3 Operation on battery power (following failure of AC input power) Transfer to battery power The AC-power source is outside tolerances, LED 17 is ON, the buzzer beeps three times. BYPASS The equipment connected to the UPS is supplied by the battery.
Test Threshold for the low-battery warning The low-battery warning threshold can be set by the user, with the UPS. Operation 3.4 Personalisation (optional) Function Personalisation parameters can be set and modified using the UPS Driver software installed on a computer that is connected to the UPS (see section 2.4 Connection to the RS232 communications port). Check that the RS232 30 cable is properly connected. UPS Driver installation: 1 - Insert the Solution-Pac CD-ROM containing the UPS Driver software in the computer drive. Operation 'Output' tab Personalisable function Default setting Options Rated UPS voltage 230 V 200 V - 208 V - 220 V - 240 V - 250 V Frequency mode Autoselect Converter Rated UPS frequency F = 50 Hz 60 Hz F ±. Operation 3.6 UPS remote power off Pulsar EXtreme C is equipped with a remote power off function (RPO) that can cut power to all the devices connected to the UPS using a remote user-operated contact. The function is implemented by opening a contact connected to the two terminals of connector 12 on the back of the UPS.
37 38 Installation and test of the remote power off function 1 - Check that the UPS is shut off and disconnected to the AC-power source. Maintenance 4.1 Troubleshooting If any of LEDs 25, 26 or 27 flash, there is a operating anomaly or an alarm. If a LED flashes, the bargraph data is no longer displayed. Indication Diagnostic Correction LED 27 flashes and the UPS overload. Maintenance Indication Signification Correction The outlets are not One of the protection circuit breakers 6 for the Check that there is not a short- supplied with power, even outlets on the back of the UPS is open.
Circuit on the outlets. Though button 16 is ON Eliminate any overloads on the (version 3200C only). Removal of battery module A - Slide a finger in the slot to remove the MGE UPS SYSTEMS logo from the front of the UPS. B - Remove the two screws. Maintenance E - Remove the screws for the battery cover. F - Remove the cover.
BYP ASS 100% test G - Remove the battery units and replace them. BYP ASS 100% test Reinstallation of the battery module Carry out the above operation in reverse order.
UPS recycling at the end of service life: MGE UPS SYSTEMS undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life (contact your MGE UPS SYSTEMS branch office). Appendices 6.1 Technical characteristics Pulsar EXtreme 2200C Pulsar EXtreme 3200C Rating 2200 VA / 1540 W 3200 VA / 2080 W AC input Voltage Single phase, 120 V / 140 V / 160 V to 284 V Frequency 50/60 Hz (auto-selection) ≥. Appendices 6.2 Glossary Authorised voltage range for Upper and lower voltage thresholds within which the UPS can operate on the automatic transfer to bypass if fault or bypass in the event of a UPS fault or overload.
Overload Automatic bypass Automatic switch controlled by the UPS, used to connect the equipment directly to the AC-power source in the event of a UPS failure or an overload. Appendices 6.3 Index Remote power off.19 Lamp test. 9 Automatic bypass. 9-18-20 LEDs.8-9 Automatic start. 17 ON LINE mode.9 Bargraph.9-15 Overload. 9-18-20 Battery End of backup time.16 Fault. Page 28 - 34007532EN/AA.